Blows warm air when cooling is on
Low refrigerant charge, an iced evaporator coil, a contactor welded shut, or a thermostat left in the wrong mode.
00 Playa Del Rey, California — Residential and light commercial
All AC & Furnace Services works on central air conditioners, furnaces, heat pumps, ductless mini-splits, ductwork and thermostats for homes and small businesses in Playa Del Rey, California.
01 Air Conditioning
The blower pulls return air across the evaporator coil, refrigerant carries that heat to the condenser outside, and supply registers put cooled air back into the rooms. When cooling falls short, the cause is usually one of three things: airflow, charge, or an electrical component.
02 Heating
Most heating calls follow a short path: the unit will not ignite, it ignites and quits, or it runs without moving enough heat. Ignition, airflow and the heat exchanger are where a visit starts.
03 Airflow
Airflow is the part of the system homeowners notice first. Rooms that never balance are usually a duct and return problem rather than a thermostat problem, and the fix starts with measurements at the registers.
A common design target is roughly 400 CFM per ton of cooling, with total external static pressure read across the filter and the coil. An undersized or blocked return is the most common reason a system loses capacity while the thermostat keeps calling.
04 Maintenance
Maintenance is not a filter change. Each item below is checked, measured and written down so the next visit has something to compare against.
Filters checked for loading, return grilles cleared, and the return path confirmed open at every room.
Condenser and evaporator coils cleaned so the refrigerant circuit can move heat the way the design expects.
Pan cleaned, drain flushed, float switch tested so a blocked line stops the unit instead of overflowing.
Capacitor values checked, contactor points inspected, amp draw recorded at the compressor and blower.
Temperature split across the coil and static pressure across filter and coil, taken and logged.
Superheat and subcooling compared against the charging chart for the installed line set length.
Burners cleaned, ignitor checked, heat exchanger inspected and flue draft verified before cold weather.
Thermostat setpoints, schedules and calibration confirmed against a handheld reference instrument.
05 Equipment
Most jobs touch the same handful of components. Knowing which cabinet you are standing in front of shortens the rest of the conversation.
06 Common Problems
Describe the symptom, the system type and where the equipment sits. These are the complaints that come up most often, with what is checked first.
Low refrigerant charge, an iced evaporator coil, a contactor welded shut, or a thermostat left in the wrong mode.
A dirty filter, low charge, short cycling from an oversized unit, or a thermostat mounted where it reads the wrong air.
A plugged condensate line, a float switch that has already tripped, or a frozen coil melting off after shutdown.
Loaded filter, crushed flex duct, dampers left closed, or a blower wheel coated in dust.
Duct leakage in an attic run, undersized returns, or branch dampers that were never balanced after work was done.
A failed ignitor, flame sensor residue, a pressure switch that will not close, or a gas valve that is not opening.
Airflow or charge. Both are corrected before refrigerant is added, or the ice returns within a day.
Dead batteries, a tripped float switch cutting the 24 volt common, or broken low-voltage wiring between the units.
07 Contact
Call or write with the equipment type, the symptom and where the unit is installed — attic, closet, side yard or roof. Model and serial numbers help if they are reachable.
Before the visit